In this work the effect of surface wettability in pool boiling heat transfer is studied. The pool boiling phenomena is characterized by three important parameters: onset boiling temperature (TONB), the heat transfer coefficient (HTC) and the critical heat flux (CHF). All these parameters are influenced by the wettability characteristics of the surface. This work analyses the effects of surface wettability on these three parameters and proposes a new super-hydrophobic polymeric coating which can have a very important effect in improving the heat pipe start-up power load and increasing the thermal performance of heat pipes when the flux is lower than the critical heat flux.
Marie, A., Miscevic, M., Lavieille, P., Lachassagne, L., and Dupont, V
Proceedings of the Joint 19th International Heat Pipe Conference and 13th International Heat Pipe Symposium, Pisa, Italy
Proceedings of the Joint 19th International Heat Pipe Conference and 13th International Heat Pipe Symposium, Pisa, Italy